•It has 7 x IEC320 C13 + 1 x IEC320 C19 socket.
• C13: 10A (Maximum); C19:16A (Maximum)
• Socket Power Measurement
Power Distribution, Space-saving 1U form, cabinet mountable, IEC or NEMA socket outlet models, 3-digit, 7-digit LED panel showing the IP address, Possibility to monitor the sockets via browser for remote users, Safe shutdown feature
The device has separate power supply for its own power and sockets.
Remote access
It can be done via TCP/IP and 10/100 Ethernet ports. Network Connections: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Pingeco PDU Power Management Supports software – eco SensorsSNMP Manager V3.
Usage
Remote sockets can be managed. Turning sockets on and off can be sequenced. Settings can be easily made via the browser. Supports IE, Firefox, Chrome, Safari browsers. RTC support when there is no electricity. Accounts can be created for 8 users and 1 administrator.
Management
The electricity coming to the PDU can be measured. The current drawn by each socket and the associated IP address are shown on the LED screen. Real-time current, voltage and kWH information can be displayed via the browser. (PE8108 / PE8208)Current and voltage settings can be made. Sockets can be named. The system provides information about event notification and system access. Software updates can be made.
Security
Two-tier securityAdvanced security - password protection and advanced encryption technology - 128 bit SSLRemote authorization support: RADIUS
eco Sensors Energy Management Software
Remote real-time power measurement and monitoringRemote real-time socket outlet power management*Automatic detection of PE devicesRemote real-time environmental monitoringMonitoring of PE devicesSMTP and Syslog alertPower Analysis Report
ModelATEN-PE8208GElectrical SpecificationsNominal Input Voltage100 – 240 VAMaximum Input Current16A (Maximum)Input Frequency50-60 HzInput ConnectionIEC 60320 C20Input Power3680 VA (Maximum)Output TypeTotal: 7 x IEC320 C13 + 1 x IEC320 C19Mon Manufactured Output Voltage 100 – 240 VAMaximum Output Current (Socket) C13 : 10A (Maximum)
C19: 16A (Maximum)Maximum Output Current (Bank)16A (Maximum)Maximum Output Current (Total)16A (Maximum)Breaker1 x 16A Non-Fuse BreakerMeteringOutlet level Current, Voltage VA , PF and KWh MonitoringSocket PassthroughAvailableEnvironmental Sensor Ports2Metering AccuracyVoltage Range : 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%Physical SpecificationsDimensions (W x L x H)43.24 x 22.04 x 4.40 cmWeight2.84 kgPower Cable Length3 metersEnvironmental FeaturesWorking Environment Temperature0 – 50°C / -20 – 60°C Humidity Rate in the Working Environment0 – 80% RH, Non-CondensingConformityEMC CertificateCE, Other OptionalSafety CertificateTUV-CB, CE-LVD, GOST, Other Optional