Space saving -1U rack mount designIEC or NEMA outlet modelsSurge ProtectionOver-current ProtectionAluminum materialWorks with data centers, server rooms and telecom equipmentFunctionPE0210SAPE0210SBPE0210SGElectricalNominal Input Voltage100-120 VAC100-240 VAC100-240 VACMaximum Input Current20A Max (UL de-dated 16A Max)20A Max (UL derating 16A Max)16A (Max)Input Frequency50-60 Hz50-60 Hz50-60 HzInput ConnectionFor A Plug: NEMA L5-20P For A2 Plug:NEMA 5-20PNEMA L6-20PFor G Plug: IEC-320 C20 For Z Plug: Chinese 16AInput Power2400VA(Max); 1920VA(UL de-rated)4800VA(Max); 3840VA(UL de-rated)3840VA(Max)Outlet Type(10) NEMA 5-20R(10) IEC 320 C13(10) IEC 320 C13Maximum Output Current (Outlet)20A Max (UL de-dated 16A Max)15A Max (UL derating 12A Max)10A (Max)Maximum Output Current (Bank)20A Max (UL de-dated 16A Max)20A Max (UL derating 16A Max)16A (Max)Maximum Output Current (Total)20A Max (UL de-dated 16A Max)20A Max (UL derating 16A Max)16A (Max)OPD(Overcurrent Protection Device)YesYesYesPhysical PropertiesDimensions (L x W x H)48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)Weight0.67 kg ( 1.48 lb )0.67 kg ( 1.48 lb )0.67 kg ( 1.48 lb )Power Cord Length10ft(12#)10ft(12#)10ft(3*2.5mm2)EnvironmentalTemperature (Operating / Storage)0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.Elevation (Operating / Storage)3000m3000m3000mComplianceEMC VerificationFCC Class AFCC Class A-Safety VerificationBy RequestBy RequestLVDNoteFor some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Space saving -1U rack mount designIEC or NEMA outlet modelsSurge ProtectionOver-current ProtectionAluminum materialWorks with data centers, server rooms and telecom equipment

FunctionPE0210SAPE0210SBPE0210SGElectricalNominal Input Voltage100-120 VAC100-240 VAC100-240 VACMaximum Input Current20A Max
(UL de-dated 16A Max)20A Max
(UL derating 16A Max)16A (Max)Input Frequency50-60 Hz50-60 Hz50-60 HzInput ConnectionFor A Plug: NEMA L5-20P
For A2 Plug:NEMA 5-20PNEMA L6-20PFor G Plug: IEC-320 C20
For Z Plug: Chinese 16AInput Power2400VA(Max);
1920VA(UL de-rated)4800VA(Max);
3840VA(UL de-rated)3840VA(Max)Outlet Type(10) NEMA 5-20R(10) IEC 320 C13(10) IEC 320 C13Maximum Output Current (Outlet)20A Max
(UL de-dated 16A Max)15A Max
(UL derating 12A Max)10A (Max)Maximum Output Current (Bank)20A Max
(UL de-dated 16A Max)20A Max
(UL derating 16A Max)16A (Max)Maximum Output Current (Total)20A Max
(UL de-dated 16A Max)20A Max
(UL derating 16A Max)16A (Max)OPD(Overcurrent Protection Device)YesYesYesPhysical PropertiesDimensions (L x W x H)48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)Weight0.67 kg ( 1.48 lb )0.67 kg ( 1.48 lb )0.67 kg ( 1.48 lb )Power Cord Length10ft(12#)10ft(12#)10ft(3*2.5mm2)EnvironmentalTemperature (Operating / Storage)0 – 40? / -20 – 60?
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.0 – 40? / -20 – 60?
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.0 – 40? / -20 – 60?
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.Elevation (Operating / Storage)3000m3000m3000mComplianceEMC VerificationFCC Class AFCC Class A-Safety VerificationBy RequestBy RequestLVDNoteFor some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Characteristics